These general instructions for the designer are provided to ensure proper selection and installation of Simpson Strong‑Tie Company Inc. products and must be followed carefully. These general instructions are in addition to the specific design and installation instructions and notes provided for each particular product, all of which should be consulted prior to and during the design process.
Moment frames are designed using Load and Resistance Factored Design (LLRFD) methodology for determining frame drift and strength limits. Allowable Stress Design (ASD) shear is determined as VASD = 0.7 x VLRFD for seismic load combinations and VASD = VLRFD/1.6 for wind load combinations.